3.4 Experimental section

Sijbren Otto - Catalysis of Diels-Alder Reactions in Water

Materials

Cu(NO3)2·3H2O (Merck), Cu(OTf)2 (Aldrich), Ni(NO3)2·6H2O (Merck), KNO3 (Merck), 2,2’-bipyridine (Merck), 1,10-phenanthroline (Merck) and N,N’-dimethylethylenediamine (Aldrich) were of the highest purity available. Ethylenediamine (Aldrich) and 2-(aminomethyl)pyridine (Aldrich) were distilled prior to use. Glycine (Fluka), L-valine (Fluka), L-leucine (Aldrich), L-phenylalanine (Jansen), L-tyrosine (Aldrich), N-methyl-L-tyrosine (Bachem), N-methyl-p-methoxy-L-phenylalanine (Bachem), L-tryptophan (Acros), 5-hydroxy-L-tryptophan (Sigma) and N-methyl-L-tryptophan (L-abrine, Aldrich) were of the highest purity available. N,N-dimethyl-L-tyrosine was synthesised as described by Bowman80. Dimineralised water was distilled twice in a quartz distillation unit. Ethanol (Merck), chloroform (Merck) and THF (Merck) were of the highest purity available. Acetonitrile (Janssen) was run over basic aluminium oxide prior to use. Cyclopentadiene (3.9) was prepared from its dimer (Merck-Schuchardt) immediately before use. The preparation of dienophiles 3.8a-g has been described in Chapter 2. Europium tris-(3-(trifluormethylhydroxymethylene or trifluoromethylhydroxymethylene (in the editors’ view))-d-camphorate) was obtained from Aldrich.

Equilibrium constants and enthalpies and entropies of complexation

Equilibrium constants for binding of 3.8a-g were determined following methods described in Chapter 2. Solutions containing copper(II) or nickel(II) α-amino acid complexes were prepared by adding a clear solution (heating may be required) of the ligand in 1-5 ml of water containing 1 equivalent of sodium hydroxide to a solution of the transition metal salt in 1-5 ml water in a volumetric flask. The required amount of potassium nitrate was added together with an amount of water sufficient to fill 95% of the volume. After dissolution of the potassium nitrate and thermal equilibration, the pH was adjusted to the desired value using diluted nitric acid and filling of the volumetric flask with water was completed.

The enthalpies of complexation of 3.8c to the copper(II) - amino acid ligand complexes have been calculated from the values of Ka at 20 °C, 25 °C, 30 °C, 40 °C and 50 °C using the van’t Hoff equation81. Complexation entropies have been calculated from the corresponding Gibbs energies and enhalpies or enthalpies (in the editors’ view).

Kinetic measurements

Kinetic experiments were performed on a Perkin Elmer λ2, λ5, or λ12 spectrophotometer following methods described in Chapter 2. Values for kcat, given in Tables 3.1 and 3.2 were calculated using equation A8, derived in Appendix 2.1 in Chapter 2.

Endo-exo selectivity

In a typical experiment 105 mg (0.50 mmol) of 3.8c, dissolved in a minimal amount of ethanol, and 100 mg (1.50 mmol) of 3.9 were added to a solution of 1.21g (5 mmol) of Cu(NO3)2·3H2O and 5 mmol of ligand in 500 ml of water in a 500 ml flask. α-Amino-acid containing solutions required addition of one equivalent of sodium hydroxide. When necessary, the pH was adjusted to a value of 5 (α-amino acids) and 7.5 (amines). The flask was sealed carefully and the solution was stirred for 2-4 hours, followed by extraction with ether. After drying over sodium sulfate the ether was evaporated. The endo-exo ratios were determined from the 1H-NMR spectra of the product mixtures as described in Chapter 2.

Enantioselective catalysis

In a typical procedure, a solution of 0.175 mmol of L-α-amino acid and 0.175 mmol of NaOH in 1 ml of water was added to a solution of 0.100 mmol of Cu(NO3)2 in 100 ml of water in a 100 ml flask. The pH was adjusted to 6.0-6.5. The catalyst solution was cooled to 0°C and a solution of 1.0 mmol of 3.8c in a minimal amount of ethanol was added, together with 2.4 mmol of 3.9. The flask was sealed carefully. After 48 hours of stirring at 0°C the reaction mixture was extracted with ether, affording 3.10c in quantitative yield. After evaporation of the ether from the water layer (rotary evaporator) the catalyst solution can be reused without a significant decrease in enantioselectivity.

Determination of the enantiomeric excess

The enantiomeric excess of 3.10c has been determined by HPLC analysis using a Daicel Chiracel OD column and eluting with a 60 / 1 (v/v) hexane(HPLC-grade) / 2-propanol(p.a.) mixture. At a flow of 1 ml per minute the rentention or retention (in the editors’ view) times for the different isomers of 3.10c were: 6.3 min. (exo, major enantiomer); 7.1 min. (exo, minor enantiomer); 7.7 min. (endo, major enantiomer); 10.7 min. (endo, minor enantiomer).

The enantiomeric excess of 3.10b and 3.10g, has been determined from 1H-NMR measurements (Varian VXR 300 MHz) in the presence of the chiral europium tris-(3-(trifluormethylhydroxymethylene)-d-camphorate) (Eu(tfc)3) shift reagent. To a solution of 100 mg of Diels-Alder adduct in 0.7 ml of CDCl3, 10-25 µl portions of a solution of 30 mg of Eu(tfc)3 in 250 µl of CDCl3 were added and the 1H-NMR spectrum was recorded. For the enantiomers of endo-3.10g, the signals of one of the vinyl protons (δ = 5.82 ppm in the absence of shift reagent) were baseline separated after addition of 65 µl (0.2 eq.) of the solution of the shift reagent. For 3.10b the singlet of the phenyl protons at 7.15 ppm (in the absence of shift reagent) was monitored. After addition of 125 µl (0.5 eq.) of the solution of the shift reagent, the enantiomeric excess was determined after integration of the signal of the minor enantiomer (7.06 ppm, s, 4H) and of half of the significantly shifted and splitted signal of the major enantiomer (7.25 ppm, d, 2H).

Determination of the enantiomeric excess of 3.10c has also been performed using Eu(tfc)3. Results obtained using this methods or this method (in the editors’ view) agreed within 2% with the outcome of the HPLC analysis.

Acknowledgements

Giovanni Boccaletti is gratefully acknowledged for the large number of experiments that paved the way to enantioselective Lewis-acid catalysis in water. Furthermore, we kindly thank the Syncom company for the use of the chiral HPLC column.